Replacement of the connection cable
The replacement of electric cable must
be carried out exclusively by the service
force centre or by personnel with similar
competencies, in accordance with the
current regulations.
To replace the connection cable use only
H03V2V2-F T90 or equivalent type.
Make sure that the cable section is
applicable to the voltage load and the
working temperature. The yellow/green
earth wire (B) must be approximately 2
cm longer than the live and neutral wire
(A).
A B
1. Connect the green and yellow (earth) wire to the
terminal which is marked with the letter 'E', or the
earth symbol
, or coloured green and yellow.
2. Connect the blue (neutral) wire to the terminal
which is marked with the letter 'N' or coloured blue.
3. Connect the brown (live) wire to the terminal which
is marked with the letter 'L'. It must always be
connected to the network phase. There must be no
cut or stray strands of wire present. The cord clamp
must be correctly attached to the outer sheath.
Assembly
1.
2.
3.
4.
50 mm
400 mm
12